ARMOR AR- 2310 UPS Trainer

Key Feature:

  • Microcontroller-Based Design: Reliability with Microchip PIC.
  • Efficient Power Stage: MOSFET-based with PWM AC output.
  • Swift Changeover: Mains to backup in less than 9 milliseconds.
  • Comprehensive Protection: Overload, short circuit, reverse phase safeguard.
  • Detailed Testing: Multiple test points for hands-on learning and troubleshooting.
  •  

    “ARMOR” made UPS TRAINER to study the working of a ups circuit different faults in a ups & troubleshooting of different faults.

     

    SPECIFICATION:

    • Based on highly reiable Microchip PIC micro ® microcontroller.
    • MOSFET based power stage, with PWM AC output.
    • Mains to Backup mode changeover time less than 9mSec.
    • Backup mode protected against Overload, short circuit, reverse phase and unbalanced MOSFET drive.
    • Line Synchronized change over from Mains to Backup and Back.
    • Over current of MOSFET’s protected within micro seconds.
    • Three step AVR with input range 140V to 280V AC. and output range 200-245V AC.
    • MOSFET based PWM battery charger.
    • Automatic low battery warning and cut off.
    • Maximum output load = 600VA

     

    Test Points & Observations:

    • Test Point 1 – AC mains voltage at the input of UPS.
    • Test Point 2 – AVR first relay control signal.
    • Test Point 3 – AVR second relay control signal.
    • Test Point 4 – AVR third relay control signal.
    • Test Point 5 – Transformer bindings for AVR section.
    • Test Point 6 – Transformer bindings for PWM section.
    • Test Point 7 – Transformer bindings for charging section.
    • Test Point 8 – AC voltage at the output of UPS.
    • Test Point 9 – Output voltage of charger (MAINS MODE) & Battery voltage (BACK UP MODE)
    • Test Point 10 – PWM 1 Signal from PIC controller.
    • Test Point 11 – PWM 2 Signal from PIC controller.
    • Test Point 12 – Control signal of buzzer from PIC controller.
    • Test Point 13 – Inverter indicator signal.
    • Test Point 14 – Output indicator signal.
    • Test Point 15 – Mains indicator signal.
    • Test Point 16 – Battery reference voltage input to PIC controller

         

    Fault & Troubleshooting:

    • Backup mode failure
    • Mains failure
    • Output failure
    • Battery failure
    • Buzzer failure
    • Mains Indicator failure
    • Output Indicator failure
    • Indicator failure
    • Battery reference voltage failure
    • Complete UPS Circuit failure (Backup & Mains Both Mode Failure)

     