Our Location
No. 10 Jalan Besar, #15-01A, Sim Lim tower, Singapore 208787
Tel: +6582987190
Email: info@armortech.sg
Social Media
Designed @ Whisperage.com
Each side has a power switch with leakage protection. Leakage current up to the technical parameter:
Input power:AC380V, 50Hz/60Hz;Three-phase, five wires.
Training projects:
● Single-phase start stop control circuit
● Asynchronous motor jog control circuit
● Asynchronous motor two ground control circuit
● Button interlocking three-phase asynchronous motor forward and reverse control circuit
● Contactor interlocked three-phase asynchronous motor positive and negative control circuit
● Double interlocked three-phase asynchronous motor positive and negative control circuit
● One-way step-down start and reverse brake control circuit
● Asynchronous motor reverse brake control circuit
● T68 trampoline lathe control circuit
● Common faults diagnosis and troubleshooting of CA6140 lathe electrical control circuit unit
Technical parameter:
● Input power: 380V±10% 50Hz ;Three-phase, five wires
● Environment: Ambient temperate range: -5 ~ 40℃
● Capacity current: AC< 0.5A
● Armature power supply< 2A
● Dimension: 1810x720x1620mm(L*W*H)
● The general power control, with leakage protection, when the leakage current reaches 30mA, the protection device
action
● 3 pcs AC voltmeter 450V with indicator
Input power:AC380V, 50Hz/60Hz;Three-phase, five wires.
Training projects:
● Single-phase start stop control circuit
● Asynchronous motor jog control circuit
● Asynchronous motor two ground control circuit
● Button interlocking three-phase asynchronous motor forward and reverse control circuit
● Contactor interlocked three-phase asynchronous motor positive and negative control circuit
● Double interlocked three-phase asynchronous motor positive and negative control circuit
● One-way step-down start and reverse brake control circuit
● Asynchronous motor reverse brake control circuit
● T68 trampoline lathe control circuit
● Common faults diagnosis and troubleshooting of CA6140 lathe electrical control circuit unit
Technical parameter:
● Input power: 380V±10% 50Hz ;Three-phase, five wires
● Environment: Ambient temperate range: -5 ~ 40℃
● Capacity current: AC< 0.5A
● Armature power supply< 2A
● Dimension: 1810x720x1620mm(L*W*H)
● The general power control, with leakage protection, when the leakage current reaches 30mA, the protection device
action
● 3 pcs AC voltmeter 450V with indicator
With a passion for pushing boundaries, we are a dynamic technology company committed to transforming possibilities into reality. By pushing the envelope of innovation, we strive to create a brighter and more connected future.
Copyright © 2024 Armor Technology Pte. Ltd.
Designed @ Whisperage.com